Thursday, March 9, 2017

Condition Monitoring Expert Tip #4 - One technology is not enough

There is no doubt that technologies such as vibration analysis, oil analysis, ultrasound and infrared are very powerful. They can tell you a great deal about fault conditions in rotating machinery, electrical systems, and more. But if the criticality warrants it, you will be in a much stronger position if you have multiple technologies indicating that a fault condition exists rather than relying on just one.

For example, if vibration analysis indicates there is a problem in a gearbox, oil analysis can confirm the fault with the presence of wear particles. In the case of vibration analysis, you can utilize high frequency analysis, spectrum analysis, time waveform analysis, and phase analysis to enable you to validate your diagnosis.

There can be a great deal at stake when you make a diagnostic call on a piece of equipment. More so if it is critical equipment. At the very least, a false diagnosis may lead to equipment failure (if you miss the fault condition) or it can lead to unnecessary work and downtime. What's more, your reputation is at stake. Sadly, people often forget when you make the right call, but it can take years for people to forget when you make the wrong call.




This tip is provided by Jason Tranter, Managing Director of Mobius Institute.

For more condition monitoring tips, continue to visit the IMVAC – International Machine Vibration Analysis Conference – blog every week. To learn more about IMVAC and the event nearest to you, visit vibrationconference.com.




No comments:

Post a Comment